"1.5 m" appears in a great many codes, but few people can explain where it comes from. This article sets out the wheelchair dimensions the geometry of the turn, and the three things most often done wrong in a columbarium.

First, a correction: 1.5 m is the diameter, not the radius. The radius is 0.75 m.
The number comes from a manual wheelchair turning 360 degrees on the spot: the chair is 1.1 m long and 0.65 m wide and rotating about its own centre sweeps an outer circle about 1.5 m in diameter.
Powered wheelchairs are larger, with a turning diameter of 1.6–1.7 m. Designing a columbarium at 1.5 m means "manual wheelchairs just fit, powered wheelchairs barely."
A standard manual wheelchair: seat width 450 mm, overall width 650 mm, overall length 1,100 mm including footrests.
Add the occupant's arms and the motion of pushing the wheels and the real occupied width is 750 mm. That is why aisles cannot be calculated at 650.
If the aisle in front of a niche is built at 1.2 m, a wheelchair in it leaves 225 mm either side — enough to stop, not enough to turn.
The correct position for a wheelchair in front of a niche is "side-on": the chair parallel to the door panel the occupant turned toward the niche.
That position requires 1.2 m of clear depth in front of the niche: 0.75 m of chair plus 0.45 m of turning clearance.
If there is only 0.9 m, a wheelchair user cannot see the centre of the door panel and has to look at an angle. That is why the worship area in front of accessible niches has to be built to 1.5 m.
A structural opening of 0.9 m, after frame and leaf gives about 0.8 m clear. A wheelchair at 0.65 m overall width leaves 75 mm either side.
That margin is only enough to go straight through, not at an angle. If a columbarium door has an 0.8 m opening, clear width drops to 0.7 m and a wheelchair has to fold its footrests to pass.
For doors into niche areas I recommend a 1.0 m opening and 0.9 m clear width.
A 1:12 slope means: for every 10 mm of rise you need 120 mm of horizontal run.
A 0.15 m level change (one step) needs a 1.8 m ramp. 0.45 m (three steps) needs 5.4 m. 1.5 m (half a storey) needs 18 m.
A ramp needs a 1.5 m deep resting landing every 9 m. Where a columbarium entrance has a level change, the ramp often occupies ten times the footprint of steps — which is why entrances should be built level.

700 mm is the grip height for a wheelchair user; 850 is for a standing pedestrian.
Fit both on ramps and stairs. The 700 one must be continuous and must have a 300 mm horizontal extension at the ends — the moment you reach for it is exactly when you need that extension.
In front of an accessible niche you can also fit a 700 mm horizontal rail to help transfer from the chair into a kneeling posture, if the family insists on kneeling.
One: the ramp is built, but there is a 30 mm threshold at the bottom. A wheelchair cannot get over it, so it might as well not exist.
Two: the accessible toilet is built, but the door opens inward. Once inside a wheelchair user cannot close the door. It must open outward or slide.
Three: the accessible niches are all in the last row. Reachable, but only by traversing the whole aisle, so the actual usage rate is very low. Accessible niches should be distributed, two to four per zone.
Accessibility in a columbarium is not "there is one somewhere" — it is "every zone can be reached."
A wheelchair user's eye level is about 1.1–1.2 m. If the centre of the niche door panel is at 1.2–1.4 m, it can be viewed level while seated.
The top tier (above 1.8 m) and the bottom tier (below 0.3 m) are effectively unusable for a wheelchair user — not because they cannot be reached, but because they cannot be seen whole.
Accessible niches should sit in the 0.6–1.4 m height band, where seated, standing and kneeling viewers can all see them.
Q: Is 1.5 m clear width or centre-to-centre?
A: Clear width. It is the minimum distance between obstacles, excluding handrails and skirting.
Q: Should powered wheelchairs get a different dimension?
A: Yes. A powered wheelchair turns in 1.6–1.7 m; if the columbarium serves an older population, design to 1.7 m to be safe.
Q: Can you widen locally instead of throughout?
A: Yes. Build 1.5 m "widened sections" in front of the niches and keep 1.2 m elsewhere. That is the best value-for-money approach.

For a wheelchair turning in a columbarium, 1.5 m is the diameter and 0.75 m the radius, derived from the outer sweep of a manual wheelchair turning on the spot. The genuinely difficult part of columbarium accessibility is not this number — it is the three fakes: the threshold, the inward-opening door, and the end-of-row position Those are what make the 1.5 m useless.