Wall thickness in aluminium profiles is the line in a niche quotation most easily faked by looking substantial. 1.2 mm and 2.0 mm look almost identical and differ in load capacity by nearly five times — and the difference is only visible if you expose an end section.

The bending stiffness of a beam scales with the cube of wall thickness. Going from 1.2 to 2.0 is a factor of 1.67, so stiffness differs by about 4.6 times.
That number matters: the uprights and beams of a niche rely on that thin wall to resist the weight of the urns and the lateral forces on the rack. On the same span, a 1.2 wall visibly sags under 30 kg while a 2.0 wall shows almost no deflection.
So the industry has an unwritten allocation: door frames and trim at 1.2–1.4; uprights and load-bearing beams no less than 1.8, preferably 2.0. Use 1.2 for a load-bearing part and nothing shows at first; by year five it starts to nod — the middle of the row sinks.
1.2 is not a product of corner-cutting; it has a defined use.
A niche door frame carries only the weight of the door (1.5–2.5 kg) and the pull of opening. The load is small, and 1.2 is entirely adequate. Thin-wall profiles also extrude easily, finish well and cost less. Making a door frame in 2.0 is waste.
The problem is using 1.2 for everything. Within one niche, the frame, upright, beam and back-panel surround carry completely different loads; build them all to the thinnest standard and the money saved comes back in year five, in the form of distortion.
Coated profiles look thicker than they are. A 0.1 mm coating on both faces makes 1.2 read like 1.4.
The more extreme trick is to give a 1.0 profile the appearance of 2.0 with wide return flanges and a thick decorative cap. From the front it is a substantial box section; expose the end and the wall is 1.0.
There is only one way to tell: look at the end section. The cut face is bare aluminium; measure it with a caliper. If you cannot reach an end, measure at a screw hole — the depth of the hole reflects the wall thickness.
Niche connections rely on self-tapping screws or blind rivets. The thinner the wall, the shorter the thread engagement and the lower the pull-out resistance.
In a 1.2 wall, an M4 self-tapper engages about 1.2 mm and holds 200–300 N; in 2.0 it reaches beyond 500 N. The beam-to-upright connection is where the load concentrates most, and if the wall is thin there the screws are slowly drawn out.
So judge the structure of a niche not by the rack as a whole but by its connections. The profile thickness at a connection is the true load capacity.

2.0 is about 60% heavier than 1.2. In a four-hundred-niche hall the frame weight can go from eight tonnes to thirteen.
Two consequences follow: the slab load has to be recalculated, and transport and installation costs rise.
So the correct approach is not "make everything 2.0" but grading: 2.0 for load-bearing parts, 1.2–1.4 for the rest. Weight and cost rise modestly and the structure still stands.
Caliper the end. Remove a decorative cap or find an unsealed end and measure directly. It is the only accurate method.
Weigh it. Among profiles of the same section, a weight difference above 50% means the wall differs. Weigh a one-metre length against the theoretical weight table.
Flex it. Grip an upright at both ends and load it: 1.2 shows slight elastic movement, 2.0 barely moves. This only shows a difference, not a value.
Drive a screw. If a self-tapper bottoms out almost immediately, the wall is too thin.
Q: Is the difference between 1.4 and 1.8 significant?
A: About 2.1 times in stiffness, but in practice 1.8 already meets niche load requirements. 1.4 is fine for a door frame and on the thin side for a beam.
Q: Is thicker always better?
A: No. A 2.0 door frame is waste and it adds load to the hinges Structural design in a columbarium means thickening where it matters, not everywhere.
Q: Is there a national standard?
A: There are wall-thickness requirements for architectural aluminium profiles, but display racking of this kind has no mandatory standard. So this is a matter of contract wording: state that load-bearing components are not less than 1.8 mm.

The 1.2 and 2.0 of a niche profile differ not by 0.8 mm but by 4.6 times the stiffness and more than double the connection strength. Door frames can be thin; uprights and beams cannot. Whether a columbarium's structure holds up is answered by one caliper reading at an end section, more reliably than by any explanation.