Column spacing looks like a structural question and is actually a setting-out question. Whether you fix it at 900 or 1200 determines how many carcass sizes a zone can hold, whether shelves need beams, and whether the layout can be altered later. Once fixed, the carcass sizes, door sizes and numbering scheme for the whole row are locked with it.

Start with the carcass. Niche carcass widths commonly come in three sizes: 300, 450 and 600 mm.
Column spacing must divide evenly by the carcass width, with 15–20 mm of installation gap at each end:
- 900 spacing: three at 300, or two at 450. - 1200 spacing: four at 300, or two at 600, or two 450 plus one 300. - 1000 spacing: two at 450 leaves 100 mm that needs a filler strip — a dirty set-out.
That is why the industry settles on 900 and 1200: they are common multiples of 300 and 450. 1000 looks tidy and needs a filler everywhere in practice.
900 spacing: each niche carries more column so more steel and 8%–12% more cost; but the shelf span is short, allowing thinner sheet (0.6 mm), and seismic performance is better.
1200 spacing: fewer columns, lower cost; but the shelf span is long and needs 0.8 mm or a cross beam, or it deflects under a full load of urns.
In a columbarium I usually suggest 1200 for standard tiers and 900 for the top and bottom The top tier often holds tablets and keepsakes — light load but requiring flatness; the bottom tier holds heavier items, where a shorter span is steadier.
Deflection is the sag at mid-span. Approximating as a simply supported beam, deflection scales with the fourth power of span: going from 900 to 1200 multiplies it by about 3.2.
A 0.6 mm galvanised shelf spanning 900 mm under 40 kg/m² sags about 1.2 mm at mid-span — invisible. Under the same conditions at 1200 mm it sags about 3.8 mm, at which point urns slide toward the middle and the door no longer closes properly.
Codes usually limit shelf deflection to 1/250 of the span, which at 1200 mm is 4.8 mm. 3.8 mm is still inside but the margin has almost gone. That is why 1200 mm demands 0.8 mm sheet or a stiffener.
Columns are the main lateral-force-resisting elements of a niche rack The wider the spacing, the more horizontal force each column carries.
Under common seismic requirements, columns are tied to structural walls at no more than 1,200 mm centres. If the column spacing is already 1200, every column needs a tie; at 900, every other one can be tied.
In seismic regions, many designs pull the spacing in to 900 precisely to make tying easier. That is not wasted steel; it is buying back safety margin.

Columns land on the slab and need expansion anchors or cast-in fixings. The anchor must fall on a structural beam or in the middle of the slab never at the slab edge. Once the base of a niche presses on a slab edge, long-term vibration cracks the corner.
With a 1200 module and a 3000 beam grid, columns will land awkwardly close to the beams. Either change the module or add a transfer beam.
So column spacing has to be fixed after the structural drawings exist, not back-calculated from a finishes layout. However elegant the niche layout, if the columns cannot land properly the whole row moves.
No dismantling, just three measurements:
1. Centre-to-centre distance between two adjacent columns — is it 900 or 1200? 2. How many carcasses sit between two columns? Divide and see whether the set-out is clean (any filler strips?). 3. Press the middle of a shelf and look for visible sag. Sagging usually means the span exceeds 1000 without a beam.
The third is the most telling. If a niche shelf gives more than 2 mm under a hand, that niche is a risk with a heavy urn.
Q: With 1200 spacing, can I fit only three 300 niches and leave 300 empty?
A: Yes, but close it with a matching infill panel or it collects dust and the row looks unfinished. The infill must be removable so a niche can be added later.
Q: An old hall has 1000 spacing — can it be changed to 1200?
A: Depends on whether the columns are movable. A fully welded frame cannot be changed; a bolted one can, but it needs new seismic ties and a fresh load check.
Q: Denser columns are steadier — why not use 900 everywhere?
A: Cost. Columns are about 30% of the steel in a niche rack; going from 1200 to 900 uses 25%–30% more steel, and that ends up in the price of every niche.

Column spacing in a niche rack is a question of common multiples of the two carcass widths, 300 and 450: 900 is steady, 1200 is economical, and everything in between needs fillers. Whether a columbarium is well set out shows in the column spacing and the cleanliness of the carcass run — whether that row has filler strips is the first test of design competence.