Travel distance is easier to overlook than width. Insufficient width is visible — people squeeze. Excess distance is invisible, until an inspector strikes it out with one sentence Columbarium niche zones are densely laid out with long aisles, and this is where the limit is most often crossed.

The distance from any point in a room to the nearest exit — measured along the actual walking path — must not exceed 22 m with a single exit, or 35 m with two.
These figures apply to general functional space. A niche zone can be treated either as a room or as a corridor; take the stricter of the two.
Niche zones frequently produce dead ends: one aisle running to the back with no exit at the far end.
Travel distance in a dead-end aisle must not exceed 20 m (25 m where sprinklers are fitted). A 30 m blind alley in a niche zone is non-compliant regardless of how wide the total is.
There is only one solution: add a cross aisle in the middle and turn it into a through route.
In a sprinkler-protected columbarium the travel distance may be increased by 25%: 22 m becomes 27.5 m, and 35 m becomes 43.75 m.
Note that this relaxation applies to distance only, never to width. Width factors in a columbarium cannot be reduced because sprinklers are installed.
Travel distance is the route a person actually walks, not a straight line between two points.
In a densely set-out niche zone, a 20 m straight line can be 30 m when walked around the rows. Draw a polyline on the plan from the most unfavourable point to the exit and measure its length.
The most unfavourable point is usually the farthest cell of the farthest row, a corner dead space, or a spot where a column blocks the sightline.
With 1.5 m row spacing and cross aisles every 15–20 m, those two numbers together determine travel distance.
At 1.5 m spacing and 18 m cross-aisle intervals, the route from the worst point out through a cross aisle to an exit is roughly 25–30 m. To hold 22 m in a columbarium, cross aisles must come down to 12–15 m intervals.
This has to be calculated on the niche layout drawing, not measured after the fit-out.

Two exits in the same wall 3 m apart satisfy the arithmetic but behave as one exit in practice.
Spread exits in different directions — one at each end, or diagonally opposite. In a long, narrow plan, exits at the two ends shorten the worst-case distance automatically.
If the columbarium also serves as a funeral or chanting hall, take the travel distance for the strictest use. During a service people are seated, density is high and they rise slowly, so the distance must be shorter.
Calculate multi-purpose space separately and do not borrow the niche zone figures. Two standards running side by side in the same building is how you avoid being told at handover that something was missed.
The order matters. Fix exit positions from the travel distance first, then size the corridors from the escape width.
Doing it the other way round — corridor width first, then look for places to put exits — produces wide aisles that lead nowhere. In a columbarium, corridor width is constrained by the niche layout and expensive to change; exit position is set at concept stage and cheap to change.
Measuring straight-line distance. 30 m walked, 20 m scaled off the drawing.
Ignoring door width. The exit exists, but the door is 0.8 m, the crowd stacks at the threshold and the effective distance grows.
Treating a stair as an exit. A stair is part of the escape path but cannot replace a means of escape leading directly outside. This matters especially on basement and semi-basement levels.
Q: Can a niche zone be treated as a corridor?
A: Yes, but corridor requirements are stricter and both ends must be open. Treating it as a corridor usually uses less area in a columbarium and is safer.
Q: Does adding sprinklers allow the relaxation?
A: Only 25%, and only with a complete sprinkler system and fire services sign-off.
Q: What if the travel distance is 3 m over?
A: Add a cross aisle, or convert one run of niches into a passage. Changing the niche layout costs far less than changing structure — but it has to be done early.

Travel distance in a columbarium: 22 m with one exit, 35 m with two, 20 m in a dead-end aisle, 25% relaxation with sprinklers, measured along the walked polyline, cross aisles every 12–15 m, exits dispersed to the two ends, and distance settled before width. The layout aesthetics of a columbarium all have to pass this piece of arithmetic — fail it and the niches can be as beautiful as you like, the doors still will not open.