The lift lobby is the most congested spot in any columbarium The cause is not too few lifts; it is that the lobby is too shallow — the doors open and the people waiting cannot step back while the people coming out cannot get clear. An elderly visitor pushing a wheelchair a family carrying a tablet, and within minutes it is a jam.

The clear depth of the lift lobby should be no less than 1.8 metres. Where the number comes from: the car is 1.4 metres deep, and when the doors open people need to turn sideways to give way, which takes 0.4 metres.
1.8 metres is only enough to "stand and wait." A wheelchair needs a 1.5 metre turning diameter, and one wheelchair plus one accompanying family member realistically needs 2.4 metres before the two stop yielding to each other.
For a columbarium lift lobby I recommend 2.4 metres. Give up one row of niches in exchange for a lobby where people can turn; the trade is worth it.
Size the waiting area by the number of people waiting at the same time, at 0.8 square metres each.
A 1,000 kilogram lift carries thirteen people at a time, so the waiting area needs roughly ten square metres. Where a columbarium's niches are concentrated on the middle and upper floors, the Qingming peak will produce twenty people waiting for one lift.
Width must also leave a through route. If the lift lobby doubles as a passage, the clear width should be no less than 2.4 metres, or the people waiting will block the aisle.
Provide one passenger lift per 2,000 to 3,000 niches.
A columbarium with 6,000 niches gets two to three. Below that, waiting time on Qingming day will exceed five minutes.
At least one of them should be a stretcher lift: clear car width no less than 1.1 metres and clear depth no less than 2.1 metres. It is in daily use too, but the dimensions cannot be cut.
Clear car door width should be no less than 1.1 metres. With a 0.9 metre door, a wheelchair has to be lifted in and out.
Buttons at 0.9 to 1.2 metres, arranged horizontally, so a seated wheelchair user can reach them. Columbarium visitors include many elderly people, and this point matters far more than the car's finishes.
Fit a mirror in the car. The mirror is not for checking appearance; it lets a wheelchair user see what is behind them in the lift and reduces the risk of being struck.
Finish the car floor in slip-resistant stone or epoxy, never carpet. There is a lot of rain, carpet absorbs water and smells within three days, and a wheelchair slips on it. The lift pit needs a sump and submersible pump, because wash-down water on the lobby floor will run down through the door gap.

The most common failure in a lift lobby is storage. Cartons, wreaths, spare shelf boards, broken niche door panels — all get put here "temporarily."
Once things are stored, the waiting area halves and the escape width is insufficient. A columbarium lift lobby should have a 1.2 metre yellow no-storage line marked out and inspected monthly.
One more rule: no incense burner and no offering table in the lobby. Someone will set a small table by the lift and burn incense, the smoke goes straight into the shaft, and the guide rails are coated within a year.
The lift lobby is where traffic splits most abruptly in a columbarium. Stepping out of the lift, a person has three seconds to decide left or right.
Put the direction sign 1.5 to 2 metres directly opposite the lift exit, at a height of 1.5 to 1.7 metres, with characters no smaller than 60 millimetres The content should be row number ranges only, not "Welcome."
A 100 millimetre guidance band on the floor, running from the lift opening to the entrance of the corresponding niche zone, works better for elderly visitors than reading signs.
My recommendation is this: a clear depth of 2.4 metres, a clear width of 2.4 metres, one lift per 2,000 to 3,000 niches, and one of them a stretcher lift.
I do not recommend turning the lift lobby into a "showroom." Sofas, flower arrangements and sales material all leave the people waiting nowhere to stand. A columbarium lift lobby needs only three things: room to turn, a clear view, and a place to queue.
Q: Can the lift lobby be merged with the entrance lobby?
A: Yes, but the waiting area must be marked out separately and must not be taken over by the lobby's waiting seating.
Q: Is one lift enough?
A: Marginally, below 3,000 niches, provided there is a goods lift or stair as a backup route.
Q: Should the lift lobby be air conditioned?
A: Recommended. Twenty people packed into ten square metres at the Qingming peak will be stifling within five minutes without it.
Q: An existing columbarium's lobby is too shallow — how do we fix it?
A: Remove the two rows of niches opposite and make up the depth to 2.4 metres. It is the only effective remedy, and the decision most worth taking early.

The lift lobby comes down to five numbers: 2.4 metres clear depth, 2.4 metres clear width, 0.8 square metres per person, one lift per 2,000 to 3,000 niches, and 1.1 metre doors. The niches in a columbarium can be stacked very high, but everyone who goes up and comes down passes through this small lobby — it is small, and it decides the dignity of a whole floor.