A columbarium moves more every day than you would expect: flower baskets offerings spare parts, cleaning carts, joss paper newly arrived urns. Route those through the visitor aisles and within a year the floor carries hundreds of scratches, and people walk into scenes they should not see.

The common service trolley in a columbarium is 600 × 900; with 150 clearance each side, the clear corridor is 1.2 m.
1.2 m lets two people pass, or one pushing a trolley while another turns sideways. Below 1.0 m the trolley has to go in at an angle; above 1.5 m is wasted area.
Widen corners to 1.5 m. Columbarium trolleys run on castors, and the rear wheels swing out about 300 in a turn.
There are three approaches.
Direct back-of-house: a goods lift or goods door opening straight into the back of house, then an internal corridor to each zone Cleanest and most expensive.
Separate goods lift: passenger and goods lifts kept apart, with the goods lift serving the back of house on each floor. Suits a multi-storey columbarium.
Time windows: no dedicated route, so restrict moving to set hours (two hours before opening, one hour after closing) and use the visitor aisles.
A columbarium needs at least one of the three. A facility with none of them will end up moving goods in the passenger lift.
The service door is 1.2 m clear double-leaf or unequal-leaf. No threshold, at most 15 mm with a bevel.
The door must self-close and be acoustically sealed when closed. If a columbarium goods door stands open, back-of-house odour and noise travel into the worship area.
Service and visitor routes will cross. Keep the number of crossings to two or fewer, both in non-ceremonial areas (the side of the foyer the back-of-house entrance).
At each crossing do three things: change the floor material (signalling "this is a route") block the sightline (a half wall or planting), and stagger the times (no moving at peak).
The worst crossing in a columbarium is one that passes through a worship area. Once the service route goes through, the positions in that zone simply stop selling.
The service corridor floor has to take trolley wheels. Use hard-wearing tile or epoxy self-levelling, R10, matte.
Do not use polished tile — rubber trolley wheels leave black marks on a polished surface that cannot be washed off. If the columbarium main aisle is polished tile, the service route must be laid separately.

The goods lift car should be 1.4 × 1.6 m clear at 1,000 kg. That takes a stretcher, a trolley plus two people.
Goods lift door 1.1 m clear, 2.1 m high. Fit a 0.9 m door and the trolley gets in but cannot turn out.
The service route must reach every back-of-house room: store, cleaner's room, plant room changing room. One room unreached and its goods are carried by hand.
Back-of-house doors 1.0 m clear, same height as the corridor, no threshold. Fit 0.8 m doors and the trolley will not go in, so everything piles at the door.
Moving in a columbarium concentrates in the two hours before opening: restocking flowers waste removal, equipment checks There is no visitor traffic then, so it is the most efficient slot.
Write moving into the duty roster and assign it to a named person. Logistics chaos in a columbarium is usually not a lack of corridors but a lack of anyone setting the time.
Using the passenger lift for goods: passenger cars have mirror and handrails, and one trolley of flower baskets scratches all of it.
Routing through a worship area: to save 5 m, the whole circulation is ruined.
Staging goods in the foyer: goods arrive and are piled in the foyer until back-of-house staff collect them. The foyer is the first impression; pile goods there once and that impression never recovers.
Q: Can a small columbarium skip a dedicated service route?
A: Below 1,000 positions, yes — but set time windows, and keep the goods and passenger lifts separate.
Q: Should the service corridor have CCTV?
A: Yes. Cameras in back-of-house corridors in a columbarium are mainly for goods and security management.
Q: Can the corridor double as an escape route?
A: Yes, but the clear width must be re-checked against the egress calculation taking the greater of the two.

A columbarium service corridor: 1.2 m clear, 1.5 m at corners, one of three routes (direct back-of-house, separate goods lift, time windows), doors 1.2 m clear with no threshold, crossings kept to two, R10 matte floor, goods lift 1.4 × 1.6, moving scheduled two hours before opening. Half the order in a columbarium is in what visitors see, and half is in this corridor they never see.